Your product may screen an error article for a variety of reasons, for instance if the battery is low. If you’re enduring an error message, the listed below images and also descriptions should aid you to identify the factor why that showing.

You are watching: What does e3 mean on a glucose meter

Blank screen


*

If the meter won’t turn on or has actually a blank display, it will be as result of one of the complying with reasons:

Dead battery – you have to insert a new one.Extreme temperatures – you require to move the meter come a much more temperate area.

Three dashes


*

If you check out 3 dashes or hyphens on your display, it way the meter is no coded or the code key is no inserted. Turn off the meter and make certain the code crucial is effectively inserted. If this walk not deal with the problem, please call rememberingsomer.com customer Care.

Battery icon


*

The battery icon means the battery power is low. Readjust the battery soon. Review this article to discover an ext about an altering the battery.

“Set-up” on display


*

The native “Set-up" displayed on the screen means the meter is in the set-up mode, waiting for girlfriend to readjust or check settings. Describe Chapter 5, "Using the Set-Up Mode", in your owner"s booklet.

“Set” on display


*

The indigenous "Set" displayed on the screen method the meter is in collection mode, wait for girlfriend to change or confirm settings. Refer to Chapter 4, "Meter Setup", in your owner"s booklet.

“Code exp” ~ above display


If you check out "code exp" presented on the screen, it way that the test strips expire in ~ the finish of the current month. Make certain the time and date in the meter are correct. If this does not deal with the problem, please call rememberingsomer.com client Care.

Flashing test strip


If a check strip symbol is flashing top top the screen, it way that the meter is ready for you come insert a test strip.

Blood fall icon


If you watch a blood drop and also test fall on the screen, it means that the meter is ready for a drop of blood or control solution.

HI in display


If you check out the letters HI shown on the screen, her blood glucose might be higher than the measuring range of the system. Refer to Chapter 4, "Unusual Blood Glucose Results", in her owner"s booklet.

LO in display


If you check out the letter LO shown on the screen, your blood glucose might be reduced than the measuring selection of the system. Refer to Chapter 4, "Unusual Blood Glucose Results", in her owner"s booklet.

Asterisk (top the screen) v blood glucose result


A star or asterisk top top the optimal of the display way a marker to be assigned to this check result.

Asterisk (bottom the screen) with blood glucose result


A star or asterisk in ~ the bottom of the display way that the test result was flagged. Refer to Chapter 3, "Flagging test Results", in her owner"s booklet for much more details.

Exclamation point


An exclamation allude on the display method blood glucose is below the identified hypoglycemic (low blood sugar) level. Refer to Chapter 4, "Unusual Blood Glucose Results", in her owner"s booklet.

“Hypo?” on display


"Hypo?" method blood glucose is below the characterized hypo (low blood sugar) level. Refer to Chapter 3, "Understanding your Test Results", in your owner"s booklet.

E-1 message


“E-1” in the display method the test strip might be damaged or the code key is incorrect. Remove and reinsert the test strip. If the message reappears, revolve off the meter and also make certain the code key is effectively inserted. If the blog post reappears, please contact rememberingsomer.com customer Care.

E-2 message


"E-2" in the display means the code vital is incorrect. Revolve the meter off and also make certain the code vital is effectively inserted. If this go not deal with the problem, please call rememberingsomer.com client Care.

E-3 message


"E-3" in the display means your blood glucose may be extremely high or a meter or a test piece error has actually occurred. The complying with instructions should assist you recognize what action to take:

If her test an outcome matches exactly how you feel, contact your healthcare expert immediately.If her test result does not complement how girlfriend feel, repeat the test and refer to chapter 4, "Unusual Blood Glucose Results", in your owner"s booklet.If the E-3 password still appears for her blood glucose test, her blood glucose an outcome may be extremely high and over the system"s reading range. Call your healthcare expert immediately.If the second test result does not enhance how girlfriend feel, execute a control test with the control solution and a brand-new test strip.If the control result is in ~ the agree range, review the appropriate testing procedure and repeat the blood glucose test v a new test strip.If the control result is not within the acceptable range, check out Chapter 2, "Understanding Out-of-Range regulate Results."

E-4 message


"E-4" in the display way not sufficient blood or control solution was attracted into the test strip for measure or was applied after the test has started. Discard the check strip and repeat the test. If the difficulty persists, please contact rememberingsomer.com client Care.

E-5 message


"E-5" in the display way the code key is incorrect or your test strips have actually expired. Make certain the time and also date in the meter room correct. If the trouble persists, please call rememberingsomer.com customer Care.

E-6 message


"E-6" in the display way blood or regulate solution was used to the check strip prior to the flashing blood drop symbol showed up on the display. Discard the test strip and repeat the test. If the problem persists, please contact rememberingsomer.com client Care.

E-7 message


"E-7" in the display means an electronic error arisen or, in rare cases, a used test piece was removed and also reinserted. Rotate the meter off and also on or take it the battery the end for 20 seconds and reinsert it. Perform a blood glucose or regulate test. If the trouble persists, please contact rememberingsomer.com customer Care.

E-8 message


"E-8" in the display way the temperature is over or listed below the proper selection for the system. Refer to the test piece package insert for system operating conditions. Relocate to an area with the proper conditions, wait 5 minutes, and also repeat the blood glucose or control test. Carry out not artificially warm or cool the meter.

E-9 message


"E-9" in the display method the battery is practically out the power. Change the battery now. If the message reappears after the battery has been replaced, reset the meter. To reset the meter, eliminate the battery, press any kind of meter button, climate reinsert the battery. For more information, and also refer to chapter 7, "Changing the Battery”, in her owner"s booklet. Alternatively, this article gives comprehensive information about transforming batteries in rememberingsomer.com products.

E-10 message


"E-10" in the display way the time and also date settings may be incorrect. Make sure the time and also date space correct and adjust the settings if necessary. For more information, describe Chapter 5, "Setting the Time and Date", in her owner"s booklet.

Err with battery icon


"Err" in the display with the battery icon means the battery is virtually out the power, so change the battery as soon as friend can. For an ext information, describe Chapter 5, "Changing the Battery", in her owner"s booklet. Alternatively, this article gives detailed information about transforming batteries in rememberingsomer.com products.

Err through time and date


"Err" in the screen with the time and also date means the time and also date settings may be incorrect. Make sure the time and also date space correct and adjust, if necessary. For more information, describe Chapter 4, "Setting the Time and also Date", in your owner"s booklet. Alternatively, this write-up gives thorough information about setting the time and also date on her device.

Err with “code” on display


"Err" in the display screen with words "code" way the code key is incorrect. Make certain the code an essential is appropriately inserted. If this doesn"t fix the problem, please contact rememberingsomer.com client Care.

Err through “code exp” ~ above display


"Err" in the display screen with the words "code exp" way the code crucial is not correct or her test strips have actually expired. Make sure the code key is properly inserted and check the date on her test strips. If this doesn"t solve the problem, please call rememberingsomer.com customer Care.

Err v flashing check strip


"Err" in the display screen with a flashing test strip means your blood sugar might be exceptionally low, or the test strip might be damaged or not appropriately inserted. If you see this error article after you applied blood to the test strip, refer to Chapter 3, "Unusual test Results", in her owner"s booklet. If you check out this error message prior to you applied blood come the check strip, eliminate the check strip and also reinsert it, or change it if damaged. If the article reappears, please call rememberingsomer.com customer Care.

Err v thermometer icon


"Err" in the display screen with a thermometer means the temperature is above or below the proper selection for the meter (43°F come 111°F). Relocate to one area in between 43°F and also 111°F, wait 5 minutes and repeat the test. Carry out not artificially warm or cool the meter.

Err with a check strip and also blood drop icons


"Err" in the display with a test strip and a blood drop means blood or control solution was applied to the check strip prior to the flashing blood drop appeared on the display. Discard the check strip and repeat the test.

Err v a blood autumn icon


"Err" in the display screen with a blood drop means not enough sample was drawn into the test piece for measure or sample was applied after the test has actually started. Discard the test strip and repeat the test.

Err alone in the display


"Err" through no other details in the display method an error arisen during the test. Discard the check strip and also repeat the test. For more information, refer to Chapter 1, "Understanding Your new System", in her owner"s booklet.

See more: Minerals Move Downward Through Soils In A Process Called, Ecology Final Flashcards

EEE in display


"EEE" in the display way an electronic error occurred. Turn the meter off and on or take the battery out for a couple of seconds and reinsert it. If the problem persists, please contact rememberingsomer.com client Care.