Pex has actually a smaller inside diameter 보다 copper. Why go pex manufactors decide the the external diameter was much more important 보다 the inside diameter?
*

Re: prestige of CTS?I think the best way to number out the answer come your question would it is in to call a PEX manufacturer, otherwise one would simply be guessing.

You are watching: What does cts mean in plumbing


*

*

Join Date: Sep 2007Posts: 4091City, State:Northern Kentucky/Greater Cincinnati AreaOccupation: -Master Plumber/Entrepreneur
Pex has actually a smaller inside diameter than copper. Why go pex manufactors decide the the external diameter was more important 보다 the inside diameter?
due to the fact that in order because that PEX to be competitive and also commingle effectively with copper, it has actually to be able to mate dimension for dimension in order to attain that. The inside diameter is lessened offered the structural high quality that is required to maintain effectiveness. IOW, They"ll never make PEX as thin together copper together it will not execute to satisfy most codes.
north Kentucky Plumbers
Twitter Feed | Plumbing Videos
*

Re: importance of CTS?My guess is that PEX morphed indigenous tubing. Common plastic and also steel pipe as offered as air lines etc. In industrial tools has always been size in OD x wall thickness. This means you can use the same fittings for thick or slim wall. I realize the pipe is the same way - the i would of 80 is much less than the identifier of 40, both with same OD, yet for some reason (my guess: v is different groups collection the requirements years ago) tube has constantly been sized in nominal OD v the fractional sizes being the standard.
Re: prominence of CTS?To match the drillbits.
*
I can"t remember the code but at once the minimum supply for a structure here was 3/4" v a schematic reflecting that the id cross-hatch of pipeline and fittings must it is in a minimum of 3/4" i m sorry 3/4" PEX can not do. Meaning, the course, the every key supply in PEX have to be a minimum the 1". Consisting of the main shutoff. I constantly wondered exactly how & why this was overlooked together I watch 3/4" PEX mains all the time.
*
J.C.
What execute all castle markings mean?PEX tube Markings
In the U.S., PEX tubing will bear number of of these marks: Manufacturer"s name and product name. NSF-61. This mark suggests that the pipe meets NSF/ANSI standard 61 for wellness requirements. NSF pw. This mark suggests that the pipe meets both NSF-61 and also NSF/ANSI standard 14 because that performance, strength and quality control. NSF rfh. This mark suggests that the pipe just meets criter for radiant floor heating. ASTM F876 and also F877. this marks indicate that the product meets requirements for dimensions and ability to stand up to pressure and also temperature. CSA B137-Series 5. This is the Canadian equivalent of the above U.S. Standards. CTS-OD. Copper tubing Size, exterior Diameter Controlled. This method that the PEX tubing"s outside diameter is made to be the exact same as the outside diameter the the same size copper tube. SDR 9. Standard measurement Ratio. Refers to the thickness that the PEX tube wall. This is the typical PEX thickness, whereby the wall is 1/9th the the external diameter the the tube.

See more: Watch Percy Jackson And The Lightning Thief Free Online Movie

ASTM F876 standard Specification for Crosslinked Polyethylene (PEX) tube ASTM F877 conventional Specification for Crosslinked Polyethylene (PEX) Plastic Hot- and also Cold-Water circulation Systems ASTM F1281 conventional Specification for Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) press Pipe ASTM F1807 standard Specification for steel Insert Fittings using a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) TubingASTM F1960 standard Specification because that Cold growth Fittings with PEX Reinforcing Rings because that Use with Cross-linked Polyethylene (PEX) tube ASTM F2023 typical Test technique for evaluating the Oxidative Resistance of Cross-linked Polyethylene (PEX) Tubing and Systems to hot Chlorinated Water. ASTM F2080 traditional Specification for Cold-Expansion Fittings with steel Compression-Sleeves because that Cross-linked Polyethylene (PEX) pipe ASTM F2098 traditional Specification because that Stainless stole Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) pipe to metal Insert Fittings check out http://www.pexinfo.com/#tubing for more.